What Is 2-3/8 In. Oil Field Tubing?
The 2-3/8 figure is a nominal outside diameter, not a bore and not a thread. Three eighths of an inch is 0.375 in., so 2-3/8 in. is 2.375 in., which converts to 60.32 mm - the figure that appears on the mill stencil, the certificate of inspection and the customs entry. The bore is a consequence of the weight designation printed after it: 4.00 lb/ft gives a 4.24 mm wall and a 51.84 mm bore, and 6.60 lb/ft on the same 60.32 mm body gives a 7.49 mm wall and a 45.34 mm bore - a wall 77 percent heavier and a flow area 23 percent smaller, on one outside diameter. A 60.32 mm tubing joint is therefore not one product with options; it is four products that happen to share a stencil.
The size sits just above the smallest API tubing, 1.900 in., and below the volume workhorse, 2-7/8 in. That position explains what it is bought for. It is the string used where the completion is small and the loads are modest: workover and recompletion strings, gas-lift and plunger-lift producers, water and disposal injection, shallow or low-rate oil wells, and the tail joints, pup joints and accessories that hang below a larger string. It is retrievable rather than cemented, so it is pulled, inspected and run again, which puts connection sealing and make-up integrity ahead of raw tonnage in the buying decision.
Two further points belong to the product rather than to the well. First, this is a seamless product in practice: the walls are thin, the tolerance on wall is −12.5 percent with no plus limit, and the thread is cut into a 4-6 mm section at the pin, so the mill route matters. Second, the standard that governs it, API 5CT / ISO 11960, is a specification for new mill product - it defines the heat, the heat treatment, the tests, the marking and the certificate, and none of those things survive a used joint being re-threaded and re-stenciled. That is not a sales point; it is the reason the certificate is a document in its own right.
2-3/8 Tubing Sizes, Weights & Dimensions
2-3/8 tubing weight per foot moves in four published steps at this outside diameter, and each one exists twice on paper because the non-upset and external-upset versions carry different nominal weights for the same wall. The 0.10 lb/ft gap between 4.60 and 4.70 is not extra steel in the body: it is the upset and the heavier coupling, counted in the nominal figure. The 2-3/8 tubing dimensions in Table 1 are pipe body only - on this size the coupling envelope is wider than the body and is set out separately below - so read the last two columns as the ones that decide whether a tool passes and whether a pump can lift the column.
Table 1 - 2-3/8 in. tubing dimensions at 60.32 mm OD (API 5CT Table C.19)
| Nominal weight NU (lb/ft) | Nominal weight EU (lb/ft) | Wall in. / mm | Nominal ID (mm) | Drift (mm) | Drift (in.) | Capacity (bbl/ft) | End finish listed |
|---|---|---|---|---|---|---|---|
| 4.00 | - | 0.167 / 4.24 | 51.84 | 49.46 | 1.947 | 0.0040 | NU only |
| 4.60 | 4.70 | 0.190 / 4.83 | 50.66 | 48.28 | 1.901 | 0.0039 | NUE and EUE |
| 5.80 | 5.95 | 0.254 / 6.45 | 47.42 | 45.04 | 1.773 | 0.0034 | NUE and EUE |
| 6.60 | - | 0.259 / 7.49 | 45.34 | 42.96 | 1.691 | 0.0031 | Plain end in most tables |
Drift = nominal ID − 2.38 mm, the API 5CT Table C.23 allowance that applies to every tubing size up to and including 2-7/8 in. Capacity is the nominal bore volume, ID² / 1029.4, and is not a flow rating. The 6.60 lb/ft line is listed as plain-end in the published tables, so its end finish has to be agreed in writing rather than assumed.
How to Read a Tubing Line
Six fields make a tubing line, and each one has a purchasing error attached to it. The outside diameter is a family, not a bore - treating 2.375 in. as the passage is how a tool gets ordered to a 51.84 mm hole. The nominal weight is a commercial designation in lb/ft, not a guaranteed shipment mass, because the same designation is reached by the body plus the coupling plus, where fitted, the upset. The nominal wall is a reference figure with a −12.5 percent tolerance, so the delivered wall can be 4.23 mm on a 4.83 mm order. The nominal ID is arithmetic: OD minus twice nominal wall. The drift is a separate, smaller number that a mandrel has actually been passed through. And the coupling outside diameter is the controlling external dimension of the string, which is the one number a clearance calculation cannot leave out.
The practical version of that list is a sentence: order the OD and weight, verify the wall and ID from a mill data sheet rather than from a catalog screenshot, and write the required drift on the purchase order if anything other than standard drift has to pass. A 2-3/8 joint is light enough to handle by hand, which is precisely why a substitution reaches the rig floor without anyone noticing - a 5.80 lb/ft joint looks like a 4.60 lb/ft joint until the drift mandrel or the pump refuses it.
Table 2 - NUE and EUE coupling dimensions at 2-3/8 in.
| End finish | Coupling OD in. / mm | Min. coupling length in. / mm | Coupling mass (kg) | Threads per inch | Thread height (mm) |
|---|---|---|---|---|---|
| NUE (NU, non-upset) | 2.875 / 73.03 | 4.250 / 107.95 | 1.28 | 10 | 1.412 |
| EUE (EU, external upset) | 3.063 / 77.80 | 4.875 / 123.83 | 1.55 | 8 | 1.810 |
Both connections are 1:16 taper, 8 or 10 round form, API 5B gauging. Regular coupling OD carries a ±1 percent tolerance, which is ±0.78 mm at 77.80 mm; the turned-down special-clearance version is held to ±0.38 mm instead.
Tubing Weight and Order Quantity
A tally written in joints and a tally written in metric tons are not the same order. Start from the nominal weight per foot, take the joint length, and then accept that the weighbridge will not agree to the kilogram: a 30 ft R2 joint at 4.70 lb/ft nominal is about 141 lb (64 kg), so a metric ton runs to roughly 15 joints, while the same joint measured cold on a scale lands either side of that by the weight tolerance. That is normal, and it is the reason a purchase order that fixes both joint count and tonnage needs one of the two marked as the governing figure.
The tonnage question also decides the shipping shape. At 60.32 mm outside diameter, tubing bundles far more joints per truck than casing does, so a 2-3/8 string is usually a bundle count rather than a truck count, and the practical constraint is handling damage to couplings and pins in transit rather than weight. Thread protectors on both ends, couplings made up to the mill's torque and not merely hand-tight, and a packing list that states joint count and measured length are worth more on this size than a precise tonnage figure.
Working a budget per joint rather than per metric ton? Ask for the 2-3/8 tubing price weight by weight - 4.00, 4.60/4.70, 5.80/5.95 and 6.60 quoted as separate lines against the same grade and end finish - because the 0.10 lb/ft between NU and EU is a coupling and an upset, and a single blended figure hides which one is being bought.
Ask for the 2-3/8 tubing price, quoting per weight line.
2-3/8 NUE and EUE Coupling Dimensions
At 2-3/8 the two API end finishes are further apart than they look in a catalog. NUE machines the thread straight into the pipe wall, so the critical section at the pin is wall minus thread depth, and the joint is inherently weaker than the body it is cut from. It also leaves the smallest external envelope on this size, 73.03 mm, and the shortest coupling, 107.95 mm, which is why a 2-3/8 NUE tubing string is the easier one to run where the restriction is tight. EUE upsets both ends before threading, so the thread is cut into added metal, the joint approaches body strength, and the 2-3/8 EUE tubing coupling grows to 77.80 mm over 123.83 mm of length. In short, the 2-3/8 tubing coupling is either 73.03 mm or 77.80 mm, and which one sits on the joint is decided by the end finish rather than by the weight.
The consequences are straightforward and both get missed. The heavier, stronger connection is the one with less room around it, so an EUE string needs 4.8 mm more radial clearance than an NUE string of the same weight before anything else shares the annulus. And the EUE coupling is a different piece of steel: 1.55 kg against 1.28 kg, which is part of why the EU nominal weight sits 0.10 lb/ft above the NU figure at the same wall.
8 Round or 10 Round: Why the Pitch Changes With the End Finish
This is the detail that separates a correct 2-3/8 order from a plausible one. On this outside diameter the thread pitch is not a property of the size; it is a property of the end finish. The non-upset joint is 10 round - ten threads per inch, 1.412 mm thread height - and the external-upset joint is 8 round, eight threads per inch, 1.810 mm thread height. The form is round in both cases - 8 round and 10 round are one round form at two pitches, not two forms - and only one of the two has eight threads to the inch.
Three things follow. A quotation written "2-3/8 8RD" is quoting the EU joint, whether or not the inquiry said so, and a buyer who wanted NU has been offered a substitution at the connection. A mill and a rig floor working on the same string need two gauge sets, not one, because a 10-round plug gauge will not gauge an 8-round pin. And a mixed shipment - NU joints for the tail and EU joints for the string - cannot be made up to each other without a crossover, which is a machined part with its own drawing and lead time, not a hardware item.
The boundary itself runs further than most tallies assume. Ten round carries the non-upset joint all the way to 3-1/2 in. and stops at 1.900 on the upset side, so every upset size from 2-3/8 in. up is 8 round while the non-upset joint of the same size is still 10 round. That makes 2-3/8 the first size at which one pipe body can carry either pitch, and the size at which a thread substitution is easiest to make and hardest to see.
Is the tally written 2-3/8 8RD or 10RD?
Send the connection line as your program writes it - size, weight, grade, end finish, and the thread callout if one is on the requisition - and the reply states which pitch that callout resolves to, which coupling OD comes with it, and what a crossover would cost if the string and the tail were ordered on different finishes. It is a two-line answer, and it prevents a whole string being re-threaded at the yard.
Three Clearance Checks Before Selecting 2-3/8 Tubing
Three dimensions have to clear three different things, and only one of them is the pipe body. The drift has to pass the tools that go inside the string; the coupling outside diameter has to pass the drift of everything the string is run through; and the upset has to be drift-checked at the ends as well as in the body. At 60.32 mm the third check is the one that surprises people, because the upset region is a different geometry from the tube it was forged onto.
Clearance Calculations - EUE Coupling vs Casing Drift
The calculation is one line: half the difference between the drift of the outer string and the coupling outside diameter. What makes it worth doing on paper is that the answer goes negative at a size most people assume is comfortable. A 2-3/8 EUE coupling at 77.80 mm will not pass the drift of 3-1/2 in. 9.20 lb/ft tubing, 72.82 mm - it is 4.98 mm too large. The non-upset coupling at 73.03 mm is still 0.21 mm too large. On API couplings, a 2-3/8 string cannot be run inside 3-1/2 tubing at all, which is the arithmetic that decides whether a small string can go inside an existing completion or has to go into casing instead.
Table 3 - Worked clearance for a 2-3/8 string, EUE coupling at 77.80 mm
| Outer string and drift | Drift (mm) | Radial clearance to the 77.80 mm coupling | Verdict |
|---|---|---|---|
| 4-1/2 in. 11.60 lb/ft casing | 98.43 | 10.32 mm | Comfortable |
| 4-1/2 in. 13.50 lb/ft casing | 96.39 | 9.30 mm | Workable |
| 4-1/2 in. 15.10 lb/ft casing | 94.01 | 8.11 mm | Workable, check the tolerance stack |
| 5-1/2 in. 17.00 lb/ft casing | 121.08 | 21.64 mm | Comfortable |
| 3-1/2 in. 9.20 lb/ft tubing | 72.82 | −2.49 mm | Will not enter |
| 3-1/2 in. 9.20 lb/ft tubing, NUE coupling 73.03 mm | 72.82 | −0.11 mm | Will not enter |
Clearances are arithmetic on the drift figures, not a design recommendation. Casing drift is the guaranteed bore; the ID is nominal and is the wrong number to calculate against. A clearance inside twice the coupling tolerance - about 1.6 mm here - is not a clearance, it is a coin toss.
Two further numbers belong in the same sum. The coupling OD tolerance is ±1 percent on the regular version, which is ±0.78 mm at 77.80 mm, and ±0.38 mm on the special-clearance version, so a nominal 8.11 mm clearance can be 7.33 mm before anything is out of round. And the grading of the restriction matters: a safety valve, a no-go nipple or a liner hanger in the path is tighter than the casing drift, so the controlling figure is the smallest bore anywhere on the way down, not the casing drift at the top.
Tool Passage Through the Pipe Body
Inside the string the governing figure is the drift, not the ID, and the 2-3/8 tubing drift diameter is a tabulated figure rather than a design choice. At 4.70 lb/ft the drift is 1.901 in. (48.28 mm) against a nominal ID of 1.995 in. (50.66 mm), and at 5.95 lb/ft it is 1.773 in. (45.04 mm) against 1.867 in. Both figures assume the standard 42 in. mandrel; a tool or a pump that is longer than the mandrel, or one with a flexible element, needs more than a pass on paper. A plug-and-gauge run, a gas-lift valve mandrel, a capillary or a wireline assembly should each be checked against the drift of the lightest line in the string, which on this size is the one that will be quoted cheapest.
The end check is the one that gets forgotten. An externally upset joint has a thicker section behind the pin, and the drift requirement applies through that section as well as through the body. Where a string has been drift-tested in the plain-end condition before coupling, the make-up can still leave an obstruction at the coupling end, and the accepted practice is to re-check from the coupling face for at least 1.1 m after make-up. Ask for the drift record to name the mandrel size and the path, not merely the word "drifted".
Does the coupling clear the hole you plan to run it through? Send the casing size and weight, or the drift of the existing string if it is already in the well, and we will put the NUE 73.03 mm and EUE 77.80 mm envelopes against it and tell you which end finish actually fits - before the string is ordered rather than after it is on the rack.
Check the coupling against your casing drift.
2-3/8 Tubing Grades & Mechanical Properties
Four grades cover almost every 2-3/8 requirement, and at this size the grade choice is driven by environment more often than by load, because the string is light and the hanging weight is rarely the limiting case. J55 is the general-purpose carbon grade and the default for workover and injection duty in sweet service. N80 is the step up in strength, supplied as N80-1 (normalized) or N80Q (quenched and tempered). L80-1 is the sour-service grade: its yield band is deliberately narrower than N80 and its hardness is capped, which is what makes it acceptable where H2S is present. P110 is the high-strength grade and is not a sour-service material at any wall.
Table 4 - Chemical composition limits for the common 2-3/8 tubing grades (% by mass)
| Grade / type | C max | Mn max | Si max | P max | S max |
|---|---|---|---|---|---|
| J55 | - | - | - | 0.030 | 0.030 |
| N80-1 / N80Q | - | - | - | 0.030 | 0.030 |
| L80-1 | 0.43 | 1.90 | 0.45 | 0.030 | 0.030 |
| P110 | - | - | - | 0.030 | 0.030 |
A dash means the standard sets no limit on that element for that grade; the mill's heat analysis still governs, and a purchaser who needs a residual limit on copper or nickel for a specific service has to write it as a supplementary requirement. L80-1 is the only grade in this list where chemistry is not the real gate - hardness is.
That last point is worth stating plainly. L80 is bought for sour service, and sour service acceptance under NACE MR0175 / ISO 15156 rests on hardness and on qualification of the material for the environment, not on the yield strength. A heat that reaches 552–655 MPa and sits at 24 HRC is not an L80 joint whatever the stencil says. The hardness cap, 23 HRC or 241 HBW, is the clause to read on the certificate, and it is the clause a re-hardened or re-threaded joint cannot demonstrate at all.
Table 5 - Mechanical properties required at 2-3/8 in. (API 5CT Table C.6)
| Grade / type | Heat treatment | Yield strength (MPa) | Tensile strength min (MPa) | Hardness max | Elongation min, 4D (%) |
|---|---|---|---|---|---|
| J55 | As-rolled or normalized | 379–552 | 517 | No requirement | 27 |
| N80-1 | Normalized | 552–758 | 689 | No requirement | 21 |
| N80Q | Quenched and tempered | 552–758 | 689 | No requirement | 21 |
| L80-1 | Quenched and tempered | 552–655 | 655 | 23 HRC / 241 HBW | 22 |
| P110 | Quenched and tempered | 758–965 | 862 | No requirement | 17 |
Elongation is calculated from the Table C.6 formula (1940 × A^0.2 / U^0.9) at the 4.83 mm wall, where A = 842 mm² and U is the specified minimum tensile strength. The figure rises on thinner walls and falls on heavier ones, so the number that binds is the one printed on the certificate for the ordered wall, not a grade headline.
Grade selection then becomes a short conversation rather than a table search. Sweet workover or disposal duty: J55 at 4.60/4.70 or 5.80/5.95. Higher pressure or a deeper set: N80, and the Q version where the mill's normalizing route is not available. Any H2S at partial pressure: L80-1, with the hardness clause read first. CO2 without H2S: the 13Cr martensitic grades, which are a different product with a different price base. Deep, high-pressure and sweet: P110, accepted with the knowledge that it buys strength and gives away toughness and sour resistance. The grade pages carry the detail: J55 casing and tubing, N80Q oil well tube, L80 Type 1 and Q125 oil tubing for the top of the range.
One sheet, one size: the four weight lines with wall, ID, drift and capacity; the NUE and EUE coupling envelopes with pitch and thread height; the grade table with the hardness clause that decides sour acceptance; and the tolerance set that acceptance at the yard is measured against. Send the weight and grade you are working to and it comes back filled in for that line, printable and attachable to a technical bid without retyping.
Get the 2-3/8 tubing specifications PDF
How to Specify 2-3/8 Tubing on an RFQ
A requisition that says "2-3/8 tubing, J55, quantity 5,000 m" will be answered, and the answer will be wrong in at least one field. Eight lines remove the ambiguity, and each of them maps to a decision that cannot be recovered later without re-cutting steel.
Size and weight - 2-3/8 in. x 4.70 lb/ft, or 60.32 mm x 4.83 mm if the requisition is metric. State the weight, not the wall, because the weight is what the mill quotes.
Grade and type - J55, N80-1, N80Q, L80-1 or P110. "L80" alone is not a grade: it is at least three materials, and only the type 1 carbon version belongs at this size in sour service.
End finish - NUE or EUE, and the thread callout if the requisition has one. This is the line that decides 10 round or 8 round, and 73.03 mm or 77.80 mm of coupling.
Drift - standard, or a stated mandrel diameter if a tool or a pump has to pass. At 4.70 lb/ft the standard figure is 48.28 mm and it does not move to suit a tool.
Range and length - the 2-3/8 tubing length range is R1, R2 or R3, and whether the string needs short joints for a workover. R2 is the default; a mixed range is a separate agreement.
Quantity - in joints, in meters or in metric tons, with the other two derivable and one of them named as governing.
Inspection - hydrostatic test pressure, non-destructive examination scope, drift record, thread gauging, and whether a third-party witness point applies.
Documents and marking - mill test report to EN 10204 3.1 (3.2 where the order calls for it), API monogram on the body, heat-number stencil, packing list with joint count and measured length.
Tubing MTC

Related Product
API 5CT N80 Type Q Tubing Pipe
FAQ
Does every new 2-3/8 tubing joint arrive with its own mill test report?
Every bundle does, and the report is issued per heat rather than per joint. It carries the heat number, the grade and type, the chemical analysis, the tensile and yield results, the hardness where the grade requires it, and the test pressures applied to that lot. Check that the heat number on the report is the number stenciled on the pipe in front of you: a report without a matching stencil describes some pipe, not necessarily this pipe.
Why is a 2-3/8 NUE joint 10 round while the EUE version of the same size is 8 round?
Because the pitch follows the end finish, not the diameter. The non-upset joint is threaded directly into the pipe wall at ten threads per inch, with a 1.412 mm thread height. The external-upset joint is threaded into forged metal at eight threads per inch, with a 1.810 mm thread height. Two gauge sets are therefore needed on the same job, and a quotation written 2-3/8 8RD is describing the EUE joint whether or not the inquiry said so.
What is the drift diameter of 2-3/8 4.70 lb/ft tubing?
48.28 mm, or 1.901 in., against a nominal inside diameter of 50.66 mm. The difference is the 2.38 mm allowance that API 5CT applies to tubing sizes up to and including 2-7/8 in., checked with a 42 in. mandrel. On the heavier 5.95 lb/ft line the drift is 45.04 mm, so the drift ladder has to be read line by line rather than taken from the outside diameter.
How many joints of 2-3/8 4.70 lb/ft tubing make a metric ton?
About fifteen, on a 30 ft R2 joint. The arithmetic is 4.70 lb/ft times 30 ft, which is 141 lb or roughly 64 kg per joint, so a metric metric ton runs to some 15.6 joints. Treat that as a planning figure only: the nominal weight is a designation that includes the coupling and the upset, the weight tolerance is −3.5 to +6.5 percent per joint, and the weighbridge figure is the one that goes on the shipping document.
Can a used or re-threaded 2-3/8 joint be supplied against an API 5CT order?
No. API 5CT describes how new pipe is made, tested, marked and certified at the mill, and a joint that has been in a well has left that process. Used tubing is inspected and graded instead - wall loss, drift, thread condition, band - and it comes with an inspection report, not a mill test report. A re-cut thread also stops being the thread the gauge was set for, because the pin length and standoff no longer measure to the drawing.
Which end finish suits a 2-3/8 workover string?
It follows from the clearance, not from habit. NUE keeps the envelope at 73.03 mm and the coupling at 107.95 mm, which is the easier joint to run where the restriction is tight, but the thread is cut into the wall so the joint is weaker than the body. EUE gives a joint close to body strength with a 77.80 mm coupling, which needs 4.8 mm more radial clearance. In 4-1/2 in. casing either fits comfortably; in 3-1/2 in. 9.20 lb/ft tubing neither will pass, at any weight.